| Short Name: | quotient |
|---|---|
| Version: |
Previously MMAT. Infrared motion track quantifies head micromovements for 15 min cont. perform. task w/ target & non-target stimuli defined by P. Green/R. Cowen Inst. for Ped. Neuroscience, Child Study Centre, New York University Langone Medical Centre
Download Definitions
Download CSV Submission Template
| ElementName | DataType | Size | Required | ElementDescription | ValueRange | Notes |
|---|---|---|---|---|---|---|
| subjectkey | GUID | Required | The NDAR Global Unique Identifier (GUID) for subjects which identifies a subject in NDAR | NDAR* | ||
| src_subject_id | String | 20 | Required | The site or study's subject identification | ||
| interview_date | Date | Required | Date on which the interview/genetic test/sampling/imaging was completed | Required field | ||
| interview_age | Integer | Required | Age in months at the time of the interview/test/sampling/imaging. | 0 :: 1200 | Age is rounded to chronological month If the research participant is 15 days old at time of interview the appropriate value would be 0 months if the participant is 16 days old the value would be 1 month | |
| mmat_ver | Float | Recommended | mmat version | |||
| rprtgenver | Float | Recommended | Report Generater version | |||
| reflectors | Integer | Recommended | number of reflectors | 0 :: 3 | ||
| mmperuevent_szeref | Integer | Recommended | a new unique event begins when this amount of distance is moved. | 0 :: 1000 | ||
| camrastr | String | 200 | Recommended | Camera version | ||
| mtsmodel | String | 200 | Recommended | motion tracking system model | ||
| resa | Integer | Recommended | motion trasking system version | 0 :: 100 | ||
| resb | Integer | Recommended | dummy variable for future description of MTS version | 0 :: 100 | ||
| framesa_percent | Float | Recommended | percentage of time reflector is detected within frame | 0 :: 100 | ||
| reflectorsa_percent | Float | Recommended | percentage of time reflector is detected | 0 :: 100 | ||
| cptacc_percent | Float | Recommended | Percentage of correct responses to both the targets and non-targets | 0 :: 100 | ||
| cpterrom_percent | Float | Recommended | Percentage of time the patient failed to respond to the target. Omission errors measure the patient's level of distraction and/or degree of inattention | 0 :: 100 | ||
| cpterrcom_percent | Float | Recommended | Percentage of incorrect responses made to the non-targets. Commission errors are a measure of the patient's impulsivity or inability to inhibit a response | 0 :: 100 | ||
| cptlatmillisecond | Integer | Recommended | Mean reaction time to respond to a target | 0 :: 400 | ||
| cptvar | Integer | Recommended | Variation (standard deviation) in response times to the correct target. High levels of variability indicate that the patient is inconsistent in the task performance | 0 :: 1000 | ||
| cptcov | Integer | Recommended | Variability that is adjusted to take into account difference in response latency. (COV = (100 * Variability) / Latency). This is a more stringent measure of response consistency. | 0 :: 100 | ||
| headimobdur | Float | Recommended | Average time not moving greater than 1 mm - based on head reflector | 0 :: 5000 | ||
| headmovmnts | Integer | Recommended | Average number of position changes >1 mm - based on head relfector | 0 :: 10000 | ||
| headdispl | Float | Recommended | Total distance traveled by the head reflector | 0 :: 50 | ||
| headarea | Integer | Recommended | Two-dimensional space in which the head reflector moved | 0 :: 2000 | ||
| headspccmplx | Float | Recommended | Describes the complexity of the movement path. Low spatial complexity values would indicate simple/back-and-forth movements | 1 :: 2 | ||
| headtmpscl | Float | Recommended | Frequency of movement with values from 0 to 1. Infrequent movements with long periods of inactivity yield values close to 0. Incessant movement produces values close to 1. | 0 :: 1 | ||
| lshinimobdur | Float | Recommended | Average time not moving greater than 1 mm - based on left shin reflector | 0 :: 5000 | Not available for child data | |
| lshinmovmnts | Integer | Recommended | Average number of position changes >1 mm - based on left shin relfector | 0 :: 10000 | Not available for child data | |
| lshindispl | Float | Recommended | Total distance traveled by the left shin reflector | 0 :: 50 | Not available for child data | |
| lshinarea | Integer | Recommended | Two-dimensional space in which the left shin reflector moved | 0 :: 2000 | Not available for child data | |
| lshinspccmplx | Float | Recommended | Describes the complexity of the movement path. Low spatial complexity values would indicate simple/back-and-forth movements | 1 :: 2 | Not available for child data | |
| lshintmpscl | Float | Recommended | Frequency of movement with values from 0 to 1. Infrequent movements with long periods of inactivity yield values close to 0. Incessant movement produces values close to 1. | 0 :: 1 | Not available for child data | |
| rshinimobdur | Float | Recommended | Average time not moving greater than 1 mm - based on right shin reflector | 0 :: 5000 | Not available for child data | |
| rshinmovmnts | Integer | Recommended | Average number of position changes >1 mm - based on right shin relfector | 0 :: 10000 | Not available for child data | |
| rshindispl | Float | Recommended | Total distance traveled by the right shin reflector | 0 :: 50 | Not available for child data | |
| rshinarea | Integer | Recommended | Two-dimensional space in which the right shin reflector moved | 0 :: 2000 | Not available for child data | |
| rshinspccmplx | Float | Recommended | Describes the complexity of the movement path. Low spatial complexity values would indicate simple/back-and-forth movements | 1 :: 2 | Not available for child data | |
| rshintmpscl | Float | Recommended | Frequency of movement with values from 0 to 1. Infrequent movements with long periods of inactivity yield values close to 0. Incessant movement produces values close to 1. | 0 :: 1 | Not available for child data | |
| attnstates | String | 200 | Recommended | Describes the attention states of the participant throughout the task. | ||
| changes | Integer | Recommended | Count of the number of attention state shifts during the test. | 0 :: 200 | ||
| att_ot | Float | Recommended | Percent of the time patient is attentive/on task, i.e., hits many targets and few non-targets | 0 :: 100 | ||
| dist | Float | Recommended | Percent of the time patient is distracted - misses some targets and hits some non-targets with accuracy better than chance | 0 :: 100 | ||
| impl | Float | Recommended | Percent of the time patient is impulsive hits many targets and some non-targets | 0 :: 100 | ||
| rand | Float | Recommended | Percent of the time patient exhibits random behavior (hits most targets and non-targets with accuaracy about as good as chance. | 0 :: 100 | ||
| min | Float | Recommended | Percent of time patient misses most targets and non-targets with accuracy about as good a chance | 0 :: 100 | ||
| cont | Float | Recommended | Percent of time patient does significantly worse than chance | 0 :: 100 |